Axcess introducer system 7F
AXcess introducer 7F is a device used to gain access to the vasculature for the purpose of obtaining blood samples, administering fluids and/or medication.
The device is designed to provide a percutaneous conduit for the atraumatic passage of other intravascular devices into the vasulature while providing hemostatic control.
KEY PRODUCT ATTRIBUTES
- Radiopaque Pebax (Polyether Block Amide) sheath material with clear PVC sideport tubing and the thermally tapered sheath design of the Argon AXcess introducer provides smooth insertion and minimises catheter peelback.
- The AXcess introducer polyurethane obturator minimises damage to vessel intimal lining whilst the Flex Collar, with suture Tab, reduces kinking risk and provides a convenient suture site.
- The siliconised valve and dilator facilitates ease of insertion and low insertion torque whilst the positive twist-lock dilator assembly prevents dilator push-back during insertion.
- The 3-Part hemostasis valve of the Argon AXcess introducer prevents bleedback by effectively sealing around the inserted wire and catheter.
TECHNICAL DATAS
- Size : 4F
- Hub color : Orange
- Introducer : Pebax sheath with ABS housing
- Valve : Silicone
- Obturator : Polyurethane
- Stopcock : Polycarbonate
- Tube : PVC
- Dilator : HDPE
- Guidewire : Stainless steel
- Latex free
- Phtalate : DEHP
- Sterile : EO
- CE 93/42/EEC Class IIa
- Box of 10
The device is designed to provide a percutaneous conduit for the atraumatic passage of other intravascular devices into the vasulature while providing hemostatic control.
KEY PRODUCT ATTRIBUTES
- Radiopaque Pebax (Polyether Block Amide) sheath material with clear PVC sideport tubing and the thermally tapered sheath design of the Argon AXcess introducer provides smooth insertion and minimises catheter peelback.
- The AXcess introducer polyurethane obturator minimises damage to vessel intimal lining whilst the Flex Collar, with suture Tab, reduces kinking risk and provides a convenient suture site.
- The siliconised valve and dilator facilitates ease of insertion and low insertion torque whilst the positive twist-lock dilator assembly prevents dilator push-back during insertion.
- The 3-Part hemostasis valve of the Argon AXcess introducer prevents bleedback by effectively sealing around the inserted wire and catheter.
TECHNICAL DATAS
- Size : 4F
- Hub color : Orange
- Introducer : Pebax sheath with ABS housing
- Valve : Silicone
- Obturator : Polyurethane
- Stopcock : Polycarbonate
- Tube : PVC
- Dilator : HDPE
- Guidewire : Stainless steel
- Latex free
- Phtalate : DEHP
- Sterile : EO
- CE 93/42/EEC Class IIa
- Box of 10
- Gauge / French
- 7F
- Length mm
- 57,5
- Packing
- BOITE 25x9x24cm
- Interventional procedure
- Vasculaire
- Gross weight
- 0,47
- Net weight
- 0,47
609413