Surface contamination meter RDS80
The RDS-80 Surface contamination meter is a versatile contamination detector which has been designed for medicine nuclear services and nuclear laboratories involving a possibility for abnormal contamination levels.
The digital, hand held pulse rate meter is suitable for personnel who need to locate and detect contaminated surfaces / objects during their work.
the functions comprise contamination measurements with alarm functions and automatic convertion to surface activity value and additionally surface contamination measurement with a possibility to store the histogram events into the meter's internal memory.
Features
- Wide measurement range : up to 100 000 cps or 1 000 000 Bq/cm²
- standard surface contamination measurements in cps or Bq/cm²
- Contamination measurements with histogram function
- Visual and audible alarms
- Handy and easy to use design
- Software for parameter setting, histogram readings and nuclide calibration
Radialogical characteristics
- Radiation detexted : Alpha >2MeV, Beta emax >100 KeV, gamma and x-raysfrom 5KeV to 1,3 MeV
- Detector : end window GM tube, 1,5-2mg/cm²
- MICA window active surface 15,2cm²
- Measurement range : surface contamination 1 to 100 000 cps or0,01 to 1 000 000 Bq/cm²
- cps linearity : ± 15 % ± 1 digit over the range. The Bq/cm² display is calculated from cps value using isotope dependent coefficients
Functional characteristics
- cps fallow up by audible signal with frequency proportional to activity
- Visual and audible alarm : user settable for surface activity
- Histogram capability of up to 480 points with user settable logging interval
- Backlight display with six large digit
- Gamma background reduction for Bq/cm² measurements
Mechanical characteristics :
- Rugged plastic case
- GM tube diameter 44mm
- Dimensions : 78x126x57mm
- Weight : 330 g with batteries
The digital, hand held pulse rate meter is suitable for personnel who need to locate and detect contaminated surfaces / objects during their work.
the functions comprise contamination measurements with alarm functions and automatic convertion to surface activity value and additionally surface contamination measurement with a possibility to store the histogram events into the meter's internal memory.
Features
- Wide measurement range : up to 100 000 cps or 1 000 000 Bq/cm²
- standard surface contamination measurements in cps or Bq/cm²
- Contamination measurements with histogram function
- Visual and audible alarms
- Handy and easy to use design
- Software for parameter setting, histogram readings and nuclide calibration
Radialogical characteristics
- Radiation detexted : Alpha >2MeV, Beta emax >100 KeV, gamma and x-raysfrom 5KeV to 1,3 MeV
- Detector : end window GM tube, 1,5-2mg/cm²
- MICA window active surface 15,2cm²
- Measurement range : surface contamination 1 to 100 000 cps or0,01 to 1 000 000 Bq/cm²
- cps linearity : ± 15 % ± 1 digit over the range. The Bq/cm² display is calculated from cps value using isotope dependent coefficients
Functional characteristics
- cps fallow up by audible signal with frequency proportional to activity
- Visual and audible alarm : user settable for surface activity
- Histogram capability of up to 480 points with user settable logging interval
- Backlight display with six large digit
- Gamma background reduction for Bq/cm² measurements
Mechanical characteristics :
- Rugged plastic case
- GM tube diameter 44mm
- Dimensions : 78x126x57mm
- Weight : 330 g with batteries
- Material
- ABS
- Colors
- Jaune
- Width mm
- 78
- Height mm
- 126
- Thickness mm
- 57
- Packing
- 35 x 25 x 25 cm
- Gross weight
- 0,5
- Net weight
- 0,33
504230